Follow this help article if you are having trouble with the #2 cook button on Town’s RM series gas rice cookers.
Technical documents such as manuals and exploded diagrams can be found here.
Now verify that the unit’s auto shut off feature is working properly.
Shut off stem assembly
Item # 56857 Mounted in the middle of the base of the unit |
Rice cooker controls |
The #1 button on the left simultaneously lights the pilot burner and triggers a piezoelectric spark. This button must be pushed down first. The #1 start button controls the piezo igniter and will pop back up after being pushed down. The red button underneath the #1 start button is what releases gas to the pilot, and will stay down when pressed. You may pull up on the red button to turn the pilot off.
The #2 button on the right lights the main burner. It must be pushed down after the #1 button and after the pilot is lit. When operating properly, this button will stay down until the rice is done cooking. It can also be pulled up to turn the main burner off.
By design, the #2 button on the RM series rice cookers can’t be pushed down without the #1 button already in the down position. Allowing the #2 button to be depressed without the #1 button down and pilot lit would release a dangerous amount of gas. Sometimes, users will mistakenly force the #2 button down before engaging the #1 button. This can bend an “L” shaped piece of metal inside the unit, causing the symptoms noted above.
On site repair of this part can be performed by someone who feels comfortable working with basic tools. The repair is purely mechanical, requiring the removal of panels and the bending of the “L” piece back to an upright position. It does not involve removing or modifying the gas line in any way. In more severe cases, the shaft that the buttons rotate around may be bent or broken, requiring its replacement. A yellow caution label on the base of the unit details the proper operating procedure.
Operating procedure sticker |
Tools Required
Before beginning, make sure the gas to the unit is off by turning the black handle on the gas valve to the vertical position. Reference the Exploded Diagram for part numbers.
Once the “L” shaped piece of metal on the #2 button arm is straightened to the vertical position and the shaft (#19) is replaced, the problem should be solved. To check, press down on the #1 button. Then push down on the #2 button. The #2 button should stay down and engaged when you remove your finger.
Illustrated repair steps |
The unit should cook all the water until it almost completely evaporates and then it should cut the main burner off. If this occurs, the rice cooker is operating properly.
If not, one or two sensors may need to be changed. See RM – Auto Shut Off Troubleshooting for more info. If these are replaced and issues are still found, contact Town for further assistance.
Town’s commercial gas rice cookers carry a 6 month mail in warranty. If your unit is under warranty, submit a repair request inquiry and we’ll be glad to assist.
We’ll process an RMA, and send you details for warranty repair. Per the warranty terms, the customer will be responsible for shipping the unit back to a designated repair facility. The original packaging must be used if available. Town is not liable for shipping damage due to insufficient packaging. If the issue is covered under warranty, Town will take care of all diagnostic, repair, and return shipping costs. We will ship the repaired unit to the shipping address provided. You may find more about our mail in warranty here.